<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki-en.dmxcontrol-projects.org/index.php?action=history&amp;feed=atom&amp;title=Group_Master_%28Master%29_DMXC3</id>
	<title>Group Master (Master) DMXC3 - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://wiki-en.dmxcontrol-projects.org/index.php?action=history&amp;feed=atom&amp;title=Group_Master_%28Master%29_DMXC3"/>
	<link rel="alternate" type="text/html" href="https://wiki-en.dmxcontrol-projects.org/index.php?title=Group_Master_(Master)_DMXC3&amp;action=history"/>
	<updated>2026-05-10T02:24:39Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.39.10</generator>
	<entry>
		<id>https://wiki-en.dmxcontrol-projects.org/index.php?title=Group_Master_(Master)_DMXC3&amp;diff=4287&amp;oldid=prev</id>
		<title>Jkuehn: Created page with &quot;{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}}  The {{Manual Objectcaption|Group Master}} are automatically created by adding a {{Manual Windowcaption|Device Group}} by default. The Group Masters control the intensity of the assigned devices. The same restriction applies as with the {{Manual Objectcaption|Grand Master}}: devices with a shutter cannot have their brightness adjusted.  = Usage = == Beh...&quot;</title>
		<link rel="alternate" type="text/html" href="https://wiki-en.dmxcontrol-projects.org/index.php?title=Group_Master_(Master)_DMXC3&amp;diff=4287&amp;oldid=prev"/>
		<updated>2025-03-03T23:17:08Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}}  The {{Manual Objectcaption|Group Master}} are automatically created by adding a {{Manual Windowcaption|&lt;a href=&quot;/index.php?title=Device_Group_DMXC3&quot; title=&quot;Device Group DMXC3&quot;&gt;Device Group&lt;/a&gt;}} by default. The Group Masters control the intensity of the assigned devices. The same restriction applies as with the {{Manual Objectcaption|&lt;a href=&quot;/index.php?title=Grand_Master_(Master)_DMXC3&quot; title=&quot;Grand Master (Master) DMXC3&quot;&gt;Grand Master&lt;/a&gt;}}: devices with a shutter cannot have their brightness adjusted.  = Usage = == Beh...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{Manual Header&lt;br /&gt;
| Type = DMXC3 Main-Software&lt;br /&gt;
| Version = 3.3.0}}&lt;br /&gt;
&lt;br /&gt;
The {{Manual Objectcaption|Group Master}} are automatically created by adding a {{Manual Windowcaption|[[Device Group DMXC3|Device Group]]}} by default. The Group Masters control the intensity of the assigned devices. The same restriction applies as with the {{Manual Objectcaption|[[Grand Master (Master) DMXC3|Grand Master]]}}: devices with a shutter cannot have their brightness adjusted.&lt;br /&gt;
&lt;br /&gt;
= Usage =&lt;br /&gt;
== Behavior in the Context of Scenes, etc. ==&lt;br /&gt;
The following table shows what output is expected on a device when the Group Master is selected in various ways and when the function value, such as the value for the dimmer, is set to different values.&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable centered&amp;quot; style=&amp;quot;text-align:center; vertical-align:middle;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! style=&amp;quot;width: 100px;&amp;quot; | Group Master !! style=&amp;quot;width: 100px;&amp;quot; | Function Value !! style=&amp;quot;width: 100px;&amp;quot; | Output&lt;br /&gt;
|-  &lt;br /&gt;
| 0 % || 100 % || 0 %&lt;br /&gt;
|-&lt;br /&gt;
| 20 % || 100 % || 20 %&lt;br /&gt;
|-&lt;br /&gt;
| 80 % || 70 % || 56 %&lt;br /&gt;
|-&lt;br /&gt;
| 20 % || 20 % || 4 %&lt;br /&gt;
|-&lt;br /&gt;
| 100 % || 0 % || 0 %&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
== Working with Nested Masters ==&lt;br /&gt;
It is allowed to assign devices to multiple {{Manual Windowcaption|[[Device Group DMXC3|Device Groups]]}}. This is particularly useful in larger lighting setups with many devices, as it makes programming various effects easier. If a device is assigned to a second device group, the intensity value stored in the scene (Cue) is multiplied by the set values of all the relevant group masters. This can look like the following:&lt;br /&gt;
&lt;br /&gt;
{| class=&amp;quot;wikitable centered&amp;quot; style=&amp;quot;text-align:center; vertical-align:middle;&amp;quot;&lt;br /&gt;
|-&lt;br /&gt;
! style=&amp;quot;width: 200px;&amp;quot; colspan=&amp;quot;2&amp;quot; | Group Master&lt;br /&gt;
! style=&amp;quot;width: 100px;&amp;quot; rowspan=&amp;quot;2&amp;quot; | Function Value&lt;br /&gt;
! style=&amp;quot;width: 100px;&amp;quot; rowspan=&amp;quot;2&amp;quot; | Output&lt;br /&gt;
|-&lt;br /&gt;
! Group 1 || Group 2&lt;br /&gt;
|-  &lt;br /&gt;
| 0 % || 0 % || 100 % || 0 %&lt;br /&gt;
|-&lt;br /&gt;
| 100 % || 20 % || 100 % || 20 %&lt;br /&gt;
|-&lt;br /&gt;
| 50 % || 50 % || 100 % || 25 %&lt;br /&gt;
|-&lt;br /&gt;
| 100 % || 50 % || 50 % || 25 %&lt;br /&gt;
|-&lt;br /&gt;
| 0 % || 100 % || 100 % || 0 %&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Because of this behavior, it might sometimes be useful to specifically deactivate group masters. This not only improves project clarity but also reduces a potential source of errors if devices output nothing.&lt;br /&gt;
&lt;br /&gt;
== Deactivating and Activating Group Masters ==&lt;br /&gt;
Unnecessary group masters can be deactivated in the settings (Properties) of the respective {{Manual Windowcaption|[[Device Group DMXC3|Device Group]]}} or reactivated if needed. When a group master is deactivated, it is automatically set to maximum brightness. If the group master is activated or deactivated for a device group, it can be viewed in the corresponding column {{Manual TableHeader|Group Master}} under the branch {{Manual Objectcaption|Device Groups}}.&lt;br /&gt;
&lt;br /&gt;
= Settings =&lt;br /&gt;
{{Manual Objectcaption|Group Masters}} themselves do not have any settings that can be specifically changed. They inherit all their settings from the associated device group. This means that, for example, if a different name is needed for the group master, the name of the associated device group must be changed. The same applies to the number of the group master.&lt;br /&gt;
&lt;br /&gt;
= External Control =&lt;br /&gt;
The Group Master can be controlled via the {{Manual Windowcaption|[[Input Assignment DMXC3|Input Assignment]]}} and returns corresponding values. There are the following nodes, which can be linked with the corresponding inputs and outputs:&lt;br /&gt;
*[[Group Master (Input Assignment) DMXC3|Group Master]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;noinclude&amp;gt;&lt;br /&gt;
[[Category: Manual DMXControl 3]]&lt;br /&gt;
[[Category: Master DMXC3]]&lt;br /&gt;
&amp;lt;/noinclude&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[de: Group_Master_(Master)_DMXC3]]&lt;/div&gt;</summary>
		<author><name>Jkuehn</name></author>
	</entry>
</feed>