User contributions for Jkuehn

Search for contributionsExpandCollapse
⧼contribs-top⧽
⧼contribs-date⧽
(newest | oldest) View ( | ) (20 | 50 | 100 | 250 | 500)

4 March 2025

  • 19:5119:51, 4 March 2025 diff hist +20,537 N Change over from DMXControl 2 to DMXControl 3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0 | Content = x }} Switching from one software to another or upgrading to a newer version often presents several challenges. In the case of transitioning from DMXControl 2 to DMXControl 3, these challenges can be summarized as follows: * DMXControl 3 operates differently in several areas compared to DMXControl 2, meaning you will need to start learning how to use it from scratch. * You have a functioning syste..."
  • 01:1101:11, 4 March 2025 diff hist +4,177 N Device (Options) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} Overview of settings (Properties) for {{Manual Windowcaption|Devices}}. {{DMXC3 Manual-Tableheader Settings | en }} {{DMXC3 Manual-Tablesection | S1 | 5 | GUI Properties }} {{DMXC3 Manual-Tablesection | S2 | 5 | Stage View }} | Display type || {{Manual Fields|Image}}<br/> {{Manual Fields|Preview}} <br/> {{Manual Fields|Custom}} || {{Manual Fields|Preview}} || {{Manual Fields|Image}}: Disp..." current
  • 01:0401:04, 4 March 2025 diff hist +6,311 N Cuelist (Options) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.3}} Overview of the settings (Properties) for the {{Manual Windowcaption|Cuelist}}. === Behavior of the Cuelist and Cues === {{DMXC3 Manual-Tableheader Settings | en}} {{DMXC3 Manual-Tablesection | S1 | 5 | General}} | Cuelist Number || Any numerical value || || |- | Priority || <code>-127</code> to<br /> <code>127</code> || 0 || Specifies which Cuelist should be executed first when multip..." current
  • 00:5600:56, 4 March 2025 diff hist 0 Category:Options DMXC3No edit summary
  • 00:5600:56, 4 March 2025 diff hist +270 N Category:Options DMXC3Created page with "This page summarizes all articles on the {{Manual_Windowcaption|Options (Options)}}, which provide various program functions and modules, but which are not included in the main article due to their scope. [Category: Manual DMXControl 3]] en: Category:Options_DMXC3"
  • 00:5300:53, 4 March 2025 diff hist +19,150 N First cuelists DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} {{Inuse}} With this article, we would like to provide you with a rough guide or checklist, so that you can quickly add a few devices to a new project through a structured approach and, at the end, be able to call up and display simple lighting moods. We will list the most important keywords in each context, so that you can easily access the relevant information whenever needed. = Setting Up Devices and..." current
  • 00:3600:36, 4 March 2025 diff hist −9 Hardware Abstraction Layer (HAL) DMXC3No edit summary current
  • 00:3500:35, 4 March 2025 diff hist +5,652 N Speed Master (Master) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Objectcaption|Speed Master}} belongs to the group of {{Manual Windowcaption|Master}} and is partially equivalent to the {{Manual Objectcaption|Parameter Master}}. With the help of the Speed Master, values of device functions (e.g., strobe frequency, gobo rotation speed) and parameters of effects (duration, frequency, ...) can be live manipul..." current
  • 00:3000:30, 4 March 2025 diff hist 0 Position Master (Master) DMXC3No edit summary current
  • 00:2800:28, 4 March 2025 diff hist −75 Position Master (Master) DMXC3No edit summary
  • 00:2700:27, 4 March 2025 diff hist −32 Position Master (Master) DMXC3No edit summary
  • 00:2700:27, 4 March 2025 diff hist +4,138 N Position Master (Master) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Objectcaption|Position Master}} belongs to the group of {{Manual Windowcaption|Master}}. As the name suggests, the Position Master allows you to live manipulate position values of devices as well as position parameters of effects. A position value consists of two values: an X and a Y position. = Usage = == Creating New Position Masters == If you want to use a Position Master..."
  • 00:2300:23, 4 March 2025 diff hist +6,128 N Parameter Master (Master) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} {{Manual Objectcaption|Parameter Master}} are a type of {{Manual Windowcaption|Master}} available in DMXControl 3, which allows you to live manipulate the values of device functions (e.g., dimmers) as well as effect parameters (Peak, Size, Phase, ...). As a general rule, the Parameter Masters can only be applied to device functions or effect parameters that do not specify a speed (frequenc..." current
  • 00:1900:19, 4 March 2025 diff hist 0 Master DMXC3No edit summary current
  • 00:1800:18, 4 March 2025 diff hist +21 Master DMXC3No edit summary
  • 00:1700:17, 4 March 2025 diff hist +3,492 N Group Master (Master) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Objectcaption|Group Master}} are automatically created by adding a {{Manual Windowcaption|Device Group}} by default. The Group Masters control the intensity of the assigned devices. The same restriction applies as with the {{Manual Objectcaption|Grand Master}}: devices with a shutter cannot have their brightness adjusted. = Usage = == Beh..." current
  • 00:1400:14, 4 March 2025 diff hist +128 N Category:Master DMXC3Created page with "This page summarizes all articles about the {{Manual_Windowcaption|Masters}}. [Category: Manual DMXControl 3]]"
  • 00:1400:14, 4 March 2025 diff hist +1,281 N Grand Master (Master) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Objectcaption|Grand-Master}} belongs to the group of {{Manual Objectcaption|Special-Masters}} and is included in every project. It controls the intensity of all {{Manual Windowcaption|Devices}} in the project, provided they have a dimmer. It doesn't matter whether this dimmer actually exists in the device or is generated by the {{Manual Windowcaption|Hardware Abstraction Lay..." current
  • 00:1000:10, 4 March 2025 diff hist +4,931 N Tracking (Cuelist) DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.2}} The {{Manual_Objectcaption|Tracking}} influences the point in time until which a value set in a cue is maintained. Whether to keep the tracking, which is enabled by default, active or disable it, depends on the use case for which the respective {{Manual_Windowcaption|Cuelist}} is prepared. = Overview = The {{Manual_Objectcaption|Tracking}} influences how long a value set in a cue for a d..." current
  • 00:0800:08, 4 March 2025 diff hist +2,572 N Cue Timing Editor DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.3}} The {{Manual_Windowcaption|Cue Timing Editor}} becomes a useful tool whenever you want to output a more complex sequence of lighting moods in a {{Manual_Windowcaption|Cuelist}} and the fading in of different functions for various devices and device groups, for example, depends on one another. To keep the associated cues simple while being able to view the entire result, you can use the {{..." current
  • 00:0400:04, 4 March 2025 diff hist 0 Cuelist Group DMXC3No edit summary current
  • 00:0400:04, 4 March 2025 diff hist +6,738 N Cuelist Group DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Windowcaption|Cuelist Group}} is a simple way to define dependencies between different {{Manual Windowcaption|Cuelists}} in DMXControl 3. = Overview = In principle, DMXControl 3 can run as many {{Manual Windowcaption|Cuelists}} in parallel as needed. It doesn't matter whether each {{Manual Windowcaption|Cuelist}} addresses different {{Manual Windowcaption|[..."
  • 00:0100:01, 4 March 2025 diff hist +8,152 N Control Panel DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.0}} The {{Manual_Windowcaption|Control Panel}} in DMXControl enhances the {{Manual_Windowcaption|Device Control}} with commonly used functions for {{Manual_Windowcaption|devices}}. This includes, among other things, dimmers, colors (Color), and position. = Overview = The {{Manual_Windowcaption|Control Panel}} in DMXControl 3 provides direct access to the most frequent..." current

3 March 2025

  • 23:5523:55, 3 March 2025 diff hist −1 Softdesk Designer DMXC3No edit summary current
  • 23:5223:52, 3 March 2025 diff hist +12,658 N Softdesk Designer DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Windowcaption|Softdesk Designer}} provides all the necessary functions to create and test a custom {{Manual Windowcaption|Softdesk}}. = Overview = The user interface built according to individual needs for live operation consists of various controls (Softdesk controls) that are later linked to the desired actions in the {{Manual Windowcaption|Input Assignment DMXC3|Input..."
  • 23:4323:43, 3 March 2025 diff hist +9,155 Softdesk DMXC3No edit summary current
  • 23:3823:38, 3 March 2025 diff hist −2 Absolute and Relative Values DMXC3No edit summary current
  • 23:3723:37, 3 March 2025 diff hist +8,318 N Absolute and Relative Values DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.3}} In DMXControl 3, you can store values for device functions as both absolute and relative values within a scene. = Overview = It is possible in DMXControl 3.2.2 to store both absolute and relative values for individual device functions in {{Manual Windowcaption|Cues}}. A typical use case for relative values are the {{Manual Windowcaption|effects}}, such as fo..."
  • 23:3323:33, 3 March 2025 diff hist −78 Log Files DMXC3No edit summary
  • 23:3223:32, 3 March 2025 diff hist −84 Log Files DMXC3No edit summary
  • 23:3123:31, 3 March 2025 diff hist +3,554 N Log Files DMXC3Created page with "Here is the translated text with the MediaWiki special characters maintained: --- {{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} In DMXControl 3, numerous actions from all program components, such as the {{Manual Windowcaption|Kernel}}, {{Manual Windowcaption|Umbra}}, and the {{Manual Windowcaption|Graphical User Interface (GUI)}}, are recorded in log files. These include, among others: * Startup procedu..."
  • 23:2823:28, 3 March 2025 diff hist −1 Project Explorer DMXC3No edit summary current
  • 23:2723:27, 3 March 2025 diff hist −290 Project Explorer DMXC3No edit summary
  • 23:2423:24, 3 March 2025 diff hist +7,396 N Project Explorer DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.2}} The entire project in DMXControl 3 is centrally managed with the {{Manual_Windowcaption|Project Explorer}}. In the Project Explorer, new {{Manual_Windowcaption|Devices}}, {{Manual_Windowcaption|Cuelists}}, {{Manual_Windowcaption|Stage Views}} etc., can be created or existing ones modified. {{Bild_mit_Unterschrift|DMXC3_Manual_Project_Explorer_Window...."
  • 23:2023:20, 3 March 2025 diff hist +4,819 N Project Administration DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} The {{Manual Windowcaption|Project Administration}} is the central location in DMXControl 3, where, as the name suggests, all projects for DMXControl 3 are managed. This includes not only the simple loading and saving of a project but also handling older (intermediate) versions of the project—whether manually saved or created via time-based automatic backups. = Overview = Organizing and managing files i..." current
  • 23:1623:16, 3 March 2025 diff hist +7,200 N Programmer DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.3}} In DMXControl 3, all paths lead to the {{Manual Windowcaption|Programmer}}. Here, all values are centrally gathered that are set by adjusting a light scene using the {{Manual Windowcaption|Device Control}} or through the {{Manual Windowcaption|Control Panel}}. Only values listed in the {{Manual Windowcaption|Programmer}} can be saved (or re-saved) in a {{Man..." current
  • 23:1023:10, 3 March 2025 diff hist 0 Settings DMXC3No edit summary current
  • 23:0923:09, 3 March 2025 diff hist +5,073 N Settings DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.1}} In the {{Manual_Windowcaption|Application and Project Settings}} both the settings for the entire program and the settings for projects are defined. = Overview = In DMXControl 3, there are three types of settings: * {{Manual_Objectcaption|Application Settings}}: These define the general settings and behavior of the software. * {{Manual_Objectcaption|Default settings for a new project}}: All settings relat..."
  • 23:0423:04, 3 March 2025 diff hist 0 Preset DMXC3No edit summary current
  • 23:0423:04, 3 March 2025 diff hist +3,709 N Preset DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} {{Manual Windowcaption|Presets}} are the central, program-wide storage for device properties used in multiple {{Manual Windowcaption|Scenes (Cues)}}. It is not necessary to adopt an entire scene; instead, you can store only a part of a saved preset in a scene. Additionally, parts of multiple presets can be used in the same scene. Furthermore, the advantage of presets is that all reference..."
  • 22:4822:48, 3 March 2025 diff hist +4 Panel Concept DMXC3No edit summary current
  • 22:4722:47, 3 March 2025 diff hist 0 Panel Concept DMXC3No edit summary
  • 22:4422:44, 3 March 2025 diff hist +1 Panel Concept DMXC3No edit summary
  • 22:4422:44, 3 March 2025 diff hist 0 Panel Concept DMXC3No edit summary
  • 22:4322:43, 3 March 2025 diff hist +11,615 N Panel Concept DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.1}} DMXControl 3 provides numerous windows that are needed more or less intensively depending on the current step in preparing a light show, etc. To create the best workspace for oneself, DMXControl 3 offers the {{Manual_Windowcaption|Panel Concept}}, allowing users to freely arrange nearly all windows. You are not limited to the main window; you can also undock as many additional windows as needed to work eff..."
  • 22:3322:33, 3 March 2025 diff hist 0 Item List DMXC3No edit summary current
  • 22:3222:32, 3 March 2025 diff hist +2,397 N Item List DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.2.2}} {{Manual Windowcaption|Item Lists}} are used to store specific color and gobo value combinations for later use in {{Manual Windowcaption|Effects}} such as the {{Manual Objectcaption|Colorchaser}} or {{Manual Objectcaption|Gobochaser}}. = Overview = The {{Manual Windowcaption|Item List}} window can be accessed via {{Manual MenuText|Windows|Project Explorer}}. = Usage = == Cre..."
  • 22:2822:28, 3 March 2025 diff hist 0 Electricity DMXC3No edit summary current
  • 22:2722:27, 3 March 2025 diff hist +3,236 N Network Concept DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} DMXControl 3 was designed from the outset to work with a distributed system. For this reason, DMXControl 3 has always consisted of several program components that all communicate via a network protocol. = Overview = DMXControl 3 is divided into several essential components due to the Network Concept: * the {{Manual Windowcaption|Graphical User Interface (GUI)}}, whi..." current
  • 22:1522:15, 3 March 2025 diff hist +4,819 N Electricity DMXC3Created page with "{{Manual Header | Type = DMXC3 Main-Software | Version = 3.3.0}} If planning is inadequate, you might face the problem of not knowing whether a power circuit will be overloaded during the show. With the {{Manual Windowcaption|Electricity Management}}, DMXControl 3 provides virtual monitoring for this issue. You can create, label, and link your power circuits with your devices. If a circuit is overloaded, you will be notified by an alert lamp in the {{Manual Windowcaptio..."
(newest | oldest) View ( | ) (20 | 50 | 100 | 250 | 500)